What exactly is the difference between a surge protector and a fuse? Can a fuse protect the electronic devices from lightning instead of surge protector?
08.06.2025 00:46

P = e* I, so since I is 16 amps, then the voltage dropped is 1/16 volt or 0.0650 volts.
There are three different concepts here that are getting confused.
“ A fuse is a device which protects the (circuit) against overload and short circuit.”
What sexual fantasies do you have?
The bolt then partially travels down the line to your home.
“ A surge suppressor is the one which is connected at the input supply so that when there is a sudden change voltage it bypasses thereby protecting the (circuit) and electronic components”
It’s been three xxx five werks, and there has been no response to my follow on query on his Commment to my answer.
Over 3,000 Private Credit Deals From Just 20 Analysts Raise Questions on Wall Street - Bloomberg.com
the problem then depends on "how fast does the fuse operate?".
If the nominal power is 4,000 watts then the current at 230volts is 16 amps.
[image of Common-mode choke]
Why cant I stop thinking about counsellor between sessions?
so, the loop of wire then, when put together with another loop reduces the ‘noise’ on a power line.
He then describes Rainy Season and Lightning.
Upvotes:
Stock futures inch lower to kick off start of the new trading month: Live updates - CNBC
What is lightning?
The third is lightning and “how it gets conducted into a home.”
So, it’s possible that these devices from Trip Lite have addition suppression devices, these ones seem to be sturdy.
How do I find a transgender girlfriend?
I post the exact comment here.
There are two important concepts here.
nine
Inflation slides to 1.9% in Europe, as worries shift from prices to Trump and tariffs - AP News
Now when you have a certain ac resistance, then a current flows in a loop.
Can the fuse protect the electronic devices from lightning instead of a surge protector.
OK, this is Mohan Rajaratnam’s definition of a Surge suppressor.
Week in Review: Perplexity Labs wants to do your work - TechCrunch
[old diagram got deleted by accident]
At the secondary, it is 1000 times less.)turns ratio). If it gets hit with a 100,000 volt bolt of lightning then the voltage arrestors conduct and clamp the voltage down to line voltage, ( but a small amount leaks down the line). This is the problem.
2024–10–00 [ Ammar Mahdi ] Ammar Mahdi
Brain Uses Separate Synapses to Balance Learning and Stability - Neuroscience News
This is where the MOV conducts again, and dissipated the energy.
At least they know the answer if they wanted it.
In schematic diagrams this is the symbol for a fuse:
Patriots decline to say whether Stefon Diggs has passed key physical in contract - NBC Sports
2024–10–11 [Victor Olarewsju Victor Olarewaju ]
This one hit behind the barn.
It seems Mohan does not understand the difference between a comment and an Answer.
Why do men choose to marry a plain Jane woman over a pretty woman?
so, what happens?
Lightning arrestor is a spark-gap device, and can be installed anywhere. What is important, is that the wire is thick enough to withstand the lightning bolt and conduct the energy away from the building.
2024–10–10[John johnson John Johnson ]
a photo is worth a thousand words.
This is a photo where a lightning bolt took out a home's complete mains distribution box, and a lot of electronic gear as well.
An AC voltage/ current source, and an ac inductive load.
The Forgotten History (and Slippery Science) of Canola Oil - Eater
what exactly is a ‘surge’ protector?
Edit 2024–10.
He then describes the function of a fuse.
Why is my ex trying to provoke an argument with me?
but this device (an Inductor) … impedes the rapid changes in the current.
This is where this question deviates from being a 'generic' question, and becomes more specific.
eight
And this is the problem alone. Is the power supply in the equipmemt designed with a lightning strike in mind? Some yes, others, no.
So, the voltage could go up to 500 volts, and the fuse will not open up.
A fuse is a non-resetable over current circuit protector.
It also is a device that limits the change in current flow.
Would individual surge supressors have save this equipment? most likely, since the surge supressor would take the jolt instead of the electronic components.
For this case there are devices called Metal oxide varistors (MOV).
First Sentence:
When the current is 200% of the rated value , it will “go open” (the link metal melts) and protect the device.
(There is no concept of polarity, in the loop because the current changes direction 100 to 120 times a second (power frequency).
But… the neutral is now “floating” because of the 1 ohm resistance.
But it can get overloaded, and no longer works.
but I think this circuit , shows a few more pieces.
At one ohm, the resistor has a maximum of 1 watt power.
This is an electronic circuit designed to clamp voltages so that the Voltage Potential that appears at the outlet is never going to exceed the nominal value.
Once the voltage goes over 0.0650 volts, then this fact can be used to amplify the difference, and turn the circuit breaker off , furthur down the line. Essentially that is what a RCD/GFCI does, it compares the incoming current, to the outgoing current, and if the difference between the two currents is over 5mA, then it trips the circuit breaker.
This is a high voltage low current spike that comes down the line because of the power poles being struck, and the voltage suppressors activating on the primary side of the transformer.
“ … to protect building, lightning arrestor, is provided above building and directly connected to earth.”
The other is “what does a “fuse” do?”
This is the picture of an electronic coil of wire wound around a core of magnetic material.
What does a fuse do?
He then asserts :
Fuses, on their own, then operate much slower than the MOV variable resistance, during the lightning strike.
2024–10–14 [Omar Gharbi Omar Gharbi ]
(Dc diagram shown, AC is similar).
Because the load is inductive, the current lags the voltage.(by a bit).
This device then solves the entire problem.
One
Barnstars:
This is 'the assistant's answer'
2024–10–16 [ OO OLAOYE OYEBODE ]
Here is a simplified AC power diagram.
So combined with a device called a MOV or Metal-oxide-resistor, then forms the 3rd part of a “surge suppressor “.
One is “what exactly is in a ‘surge protector’ ? ”
2024–10–11 [Bobby Sanchez Bobby Sanchez ].
The MOV will conduct when the voltage exceeds 50% of line voltage.
These devices are installed between the “hot” and “neutral” and protective ground.
But during the surge, the fuse will not blow if it is a longer duration and lower value )10 to 50%).
2024–09–27 [ Mohan Rajaratnam Mohan Rajaratnam ] . Thinks you can get free electricity from nothing : Mohan Rajaratnam's answer to Is it possible to generate free electricity at home using a magnet or other low-cost methods? If so, how does it work?
Mohan forgets that a fuse is a one-time device, and needs to be replaced if it is tripped.
Is the question then , "why buy a surge supressor, if the fuse alone protects the electronic circuits from a lightning bolt?".
A circuit breaker is similar, but is resettable.
These are simplified answers to the original question, and does not change anything I wrote above.
There is no harm in having the surge suppressor along with the fuse in the circuit. The fuse will not open up until the current melts the link. This will take time, and in the interim, that jolt will get transmitted into the power supplies.